ENpartial discharge extinction voltage (Ue) 
lowest peak value of the test voltage at which the apparent charge becomes less than the specified discharge magnitude when the test voltage is reduced below a high level where such discharges have occurred

NOTE For a.c. tests the r.m.s. value may be used.


TC/SC:82Terms     Info     Publications
Published in:IEC 62109-1, ed. 1.0 (2010-04) Terms     Info
Reference number:3.52
Source:IEC 60664-1