ENdielectric dissipation factor (tan δ), DDF 
dielectric dissipation factor, DDF, (tan d) of an insulating material is the tangent of the loss angle.

The loss angle is the angle by which the phase difference between applied voltage and the resulting current deviates from p/2 rad when the dielectric of the capacitor consists exclusively of the insulating material

NOTE For practical purposes, measured values below 0,005 for tan d and power factor are essentially the same. A simple conversion can be used to convert one to the other. The power factor is the sine of the loss angle and the relationship between power factor and dielectric dissipation factor can be expressed as follows:



FRfacteur de dissipation diélectrique (tan δ), DDF  
facteur de dissipation diélectrique, (tan d) d'un isolant est la tangente de l'angle de pertes.

L'angle de pertes est l'angle pour lequel la différence de phase entre la tension appliquée et le courant qui en résulte dévie de p/2 rad lorsque le diélectrique du condensateur se compose exclusivement de l’isolant

NOTE Pour des raisons pratiques, la tan d (pour les valeurs mesurées inférieures à 0,005) et le facteur de puissance (PF en anglais) sont essentiellement les mêmes. Une simple conversion peut être utilisée pour convertir l’une en l’autre. Le facteur de puissance est le sinus de l’angle de pertes et la relation entre le facteur de puissance et le facteur de dissipation diélectrique peut être exprimée comme suit:




TC/SC:10Terms     Info     Publications
Published in:IEC 60247, ed. 3.0 (2004-02) Terms     Info
Reference number:3.2