(Unit: W, J, though kWh is commonly used in the electrical industry)
electric power or energy that does not result in the service that is intended
NOTE 1 See also IEV 151-15-26
a) array capture losses
(Symbol: Lc)
normalised losses of a given PV system due to the energy losses of its PV array
NOTE 2 PV array capture losses are found from the difference between the reference yield and the PV array yield. These losses arise from mis-match losses, conversion losses, array soiling, etc
b) balance of system losses
(Symbol: LBOS)
normalised losses of a given PV system due to the energy losses of its BOS components
c) normalised losses
(Unit: J ´ kW–1 Usually expressed as kWh ´ kW–1 over any convenient unit of time. Commonly it is calculated over a day, which then gives a unit of h ´ d–1)
duration that a PV device or PV system would need to operate at its rated power to compensate for the energy losses of that PV device or PV system
NOTE 3 Normalised losses are commonly calculated from a difference in given yields |