Area: 444: Elementary relays           Index language:

Hide details for [<u>Section 444-01: Relay types</u>]Section 444-01: Relay types
444-01-01
electrical relay
444-01-02
all-or-nothing relay
444-01-03
elementary relay
444-01-04
electromechanical relay
444-01-05
electromagnetic relay
444-01-06
solid-state relay
444-01-07
monostable relay
444-01-08
bistable relay
444-01-09
polarized (elementary) relay
444-01-10
non-polarized relay
444-01-11
relay technology categories
Hide details for [<u>Section 444-02: Conditions and operations</u>]Section 444-02: Conditions and operations
444-02-01
release condition (for elementary relays)
444-02-02
operate condition (for elementary relays)
444-02-03
hold condition (of a monostable relay)
444-02-04
operate (for elementary relays) verb
444-02-05
release, verb
444-02-06
reset (for elementary relays) verb
444-02-07
change over (for elementary relays) verb
444-02-08
cycle (for elementary relays) verb
444-02-09
revert, verb
444-02-10
revert reverse, verb
444-02-11
cycle (for elementary relays), noun
444-02-12
frequency of operation
444-02-13
continuous duty
444-02-14
intermittent duty
444-02-15
duty factor
444-02-16
temporary duty
444-02-17
thermal resistance
444-02-18
rated value
444-02-19
characteristic value
444-02-20
test value
444-02-21
actual value
Hide details for [<u>Section 444-03: Energization</u>]Section 444-03: Energization
444-03-01
energizing quantity (for elementary relays)
444-03-02
input circuit (for elementary relays)
444-03-03
input voltage
444-03-04
energize a relay (for elementary relays) verb
444-03-05
operate range of the input voltage
444-03-06
operate voltage
444-03-07
non-operate voltage
444-03-08
release voltage
444-03-09
non-release voltage
444-03-10
reset voltage
444-03-11
non-reset voltage
444-03-12
revert voltage
444-03-13
non-revert voltage
444-03-14
revert reverse voltage
444-03-15
non-revert reverse voltage
444-03-16
reverse polarity voltage
444-03-17
rated power of the input circuit
444-03-18
limiting continuous thermal withstand power
444-03-19
magnetic preconditioning value
444-03-20
coil transient suppression device
Hide details for [<u>Section 444-04: Output circuits</u>]Section 444-04: Output circuits
444-04-01
output circuit
444-04-02
contact circuit
444-04-03
contact (for elementary relays)
444-04-04
contact set
444-04-05
contact member (for elementary relays)
444-04-06
contact point
444-04-07
single contact
444-04-08
bifurcated contact
444-04-09
contact gap
444-04-10
contact force
444-04-11
contact follow
444-04-12
contact wipe
444-04-13
effectively conducting output circuit
444-04-14
effectively non-conducting output circuit
444-04-15
output make circuit (for elementary relays)
444-04-16
output break circuit (for elementary relays)
444-04-17
make contact (for elementary relays)
444-04-18
break contact (for elementary relays)
444-04-19
change-over contact
444-04-20
change-over make-before-break contact
444-04-21
change-over break-before-make contact
444-04-22
reed contact
444-04-23
forcibly guided contacts
444-04-24
switching power
444-04-25
contact voltage
444-04-26
contact current
444-04-27
switching current
444-04-28
limiting continuous current of an output circuit
444-04-29
limiting short-time current of an output circuit
444-04-30
limiting making capacity
444-04-31
limiting breaking capacity
444-04-32
limiting cycling capacity
444-04-33
contact noise
444-04-34
contact bounce
444-04-35
contact chatter
444-04-36
categories of application of contacts
Hide details for [<u>Section 444-05: Times</u>]Section 444-05: Times
444-05-01
operate time (for elementary relays)
444-05-02
release time (for elementary relays)
444-05-03
reset time (for elementary relays)
444-05-04
bounce time
444-05-05
bridging time
444-05-06
transfer time
444-05-07
stabilization time (for elementary relays)
444-05-08
minimum time of energization (for operation)
Hide details for [<u>Section 444-06: Influence quantities</u>]Section 444-06: Influence quantities
444-06-01
influence quantity
444-06-02
reference value of an influence quantity
444-06-03
reference conditions of influence quantities
444-06-04
nominal range of an influence quantity
444-06-05
extreme range of an influence quantity
Hide details for [<u>Section 444-07: Endurance</u>]Section 444-07: Endurance
444-07-01
relay reliability
444-07-02
relay failure (for elementary relays)
444-07-03
(intermittent) relay fault (for elementary relays)
444-07-04
relay defect
444-07-05
defective relay
444-07-06
mean operating time between failures
444-07-07
cycle-related mean operating time between failures
444-07-08
relay failure rate
444-07-09
cycle-related failure rate
444-07-10
mechanical endurance
444-07-11
electrical endurance
444-07-12
relay endurance test
444-07-13
contact fault due to increased contact-circuit resistance
444-07-14
contact fault due to non-opening of the contact circuit
444-07-15
contact failure
444-07-16
final endurance value