differential ionization chamber designed to measure a particular type of radiation where an interfering type of radiation is also present
Note 1 to entry: The compensation is designed to significantly reduce the influence of gamma radiation for neutron detection in a mixed neutron-gamma field. Note 2 to entry: This entry was numbered 394-25-20 in IEC 60050-394:2007.
|