IEVref:531-46-43ID:
Language:enStatus: Standard
Term: recovery period (for blocking tubes)
Synonym1:
Synonym2:
Synonym3:
Symbol:
Definition: the time interval between the instant at which the radio-frequency ionizing pulse ceases and the instant at which the attenuation of a low-power signal by the blocking tube falls to a stated level


Publication date:1974
Source
Replaces:
Internal notes:2016-01-04: Editorial correction of "radio frequency xxxx" to "radio-frequency xxxx". JGO